Page 2
The information in the relevant documentation must be observed. Trademarks All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Page 3
Agilion GmbH Blankenauer Straße 74 09113 Chemnitz Germany Tel.: +49 - (0)371 - 45 00 48-0 Fax.: +49 - (0)371 - 45 00 48-11 www.agilion.de service@agilion.de Management: Andreas Werner Johannes Waldhör Sven Sieber HR B 21249 Chemnitz USt.-IdNr.: DE236591552 SIMATIC RTLS4030G Device manual, 10/2018, C79000-G8976-C515-01...
Table of contents English Overview ..............................6 General ..............................6 Delivery contents ............................6 Power supply ............................. 6 Application field ............................6 Layout and connections ........................... 7 Dimensions ..............................7 Connections and displays ......................... 7 2.2.1 Possible states of the LEDs ........................8 Pin allocation .............................
Page 5
Approvals .............................. 14 EU declaration of conformity ........................14 RoHS ............................... 14 RED ................................. 15 6.3.1 Protection of health and safety ....................... 15 Recycling and disposal ..........................16 SIMATIC RTLS4030G Device manual, 10/2018, C79000-G8976-C515-01...
1 Overview 1.1 General The gateway SIMATIC RTLS4030G represents, like the SIMATIC RTLS4030A, a basing point for the localization within the Wireless Location System (WLS). The gateway can be connected to the local IT-infrastructure via Ethernet. Through this connection the nodes (anchors and gateways) will exchange the localization data gathered as well as customer specific data between the localization network and the localization server.
2 Layout and connections 2.1 Dimensions Power Radio Network Power Venting Ethernet 2.2 Connections and displays Connection Description Power Electricity supply Ethernet RJ45 Ethernet with PoE, Amphenol LTW RCP-00AMMA-TLM7001 Display Description Power LED (green/red) LED signaling electricity supply LED signaling the activity of the WLS (sending and receiving Radio LED (yellow) radio signals) Network LED (blue)
2.2.1 Possible states of the LEDs Power LED status display Description (green/red) On (green) Power supply via cord Flashes red every second Undervoltage Radio LED status display (yellow) Description Device’s WLS radio disabled Flashes Device’s WLS radio active Network LED status display (blue) Description Network connection established via LAN (Ethernet) Network connection established but no connection to...
2.3 Pin allocation 2.3.1 Power, digital output – plug-in connector Power 3-pole connector Buccaneer® PX0412/03P Pins: SA3350/1 Sealing cap: PX0480 Digital output Description 1 - Power (red) 8 … 30 V DC 2 - GND (black) GND (0 V) 3 - Digital output (brown) Switched input voltage, maximum current (I) 200 mA 2.3.2 Ethernet socket RJ45 The device may only be connected to the Ethernet using the connectors depicted below.
3 Installation, initial start-up, safety 3.1 General information The devices can only be used in combination with the WLS. • Buildup, installation as well as the use of the tools and clients of the localization system are • described in the corresponding guides and manuals. 3.2 Installation Carefully read all items listed in section 3 (Installation, initial start-up, safety) before installing •...
3.3.1 Power supply When connecting the power supply to the power connector, all LEDs flash for an instant. The • power LED is on, if power is supplied (cf. states of the LEDs 2.2.1). The device can be powered via Ethernet cable. In this case the power supply connector should •...
4 Troubleshooting 4.1 General errors Fault detection Cause of error Troubleshooting Wireless module does not Module is not connected or power Check module’s power supply react, all LEDs are off supply is not switched on. Power LED (red) flashes Undervoltage Check power supply every second Radio LED (yellow) is off...
09113 Chemnitz Bundesrepublik Deutschland You can find the current EU declaration of conformity for these products on the Internet pages under Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/14970/cert) The products described in this document meet the requirements of the following EC directives: RoHS directive 2011/65/EU •...
6.3 RED 6.3.1 Protection of health and safety The products described in this document meet the requirements of the applied standards: Article 3 (1) a) protection of health and safety • EN 62368-1 Information technology equipment - Safety - Part 1: General requirements •...
Do not dispose of the products at public disposal sites. For environmentally compliant recycling and disposal of your electronic waste, please contact a company certified for the disposal of electronic waste or your Siemens representative. Note the different national regulations.
Page 17
Important information for use in the USA: This equipment may only be operated indoors. Operation outdoors is in violation of 47 U.S.C. • 301 and could subject the operator to serious legal penalties. This equipment has been tested and found to comply with the limits for a Class A digital device, •...
Page 18
Appendix 1 - Quick installation guide not included in Anchor black = GND red = Power brown = digital out 20170315-Drilling template MESH SIMATIC RTLS4030G Device manual, 10/2018, C79000-G8976-C515-01...
Page 19
Drilling template on a scale of 1:1 All dimensions in millimeters SIMATIC RTLS4030G Device manual, 10/2018, C79000-G8976-C515-01...