Procedure
1. Choose the "Port Configuration" menu from the home page.
2. Activate (for example) port 1 via the check box.
Note: On the port configuration home page, all the eight ports are displayed and activated
by default.
3. Click the toggle button to select the port mode for port 1.
– Auto (default): The device identifies the converter at the port automatically.
– Manual: You need to set the basic parameters of the converter at the port manually.
Note: If you select the automatic port mode, you need to press the USER button on the
device to complete the identification or wait for the device to identify the converter by
itself. For more information, see Section "Identifying the converter (optional) (Page 36)".
4. Assuming that you select the manual port mode, click "Converter Settings" to start setting
the basic parameters of the port.
Note: When the automatic port mode is selected, the "Converter Settings" button is
disabled. In this case, click "Parameters" to directly start configuring converter parameters
(skip to step 7).
5. In the window that opens, select, from the drop-down lists, the desired converter type,
USS address, and transmission baud rate respectively.
6. Click "Save" to activate the parameter settings or click "Cancel" to cancel the settings.
SINAMICS CONNECT
Operating Instructions, 10/2018, A5E45421408
Configuring the device
5.2 Standard Web pages