Test operation of the servo motor alone in test operation mode

• If the servo motor operates abnormally, stop the servo motor with EM2 (Forced stop 2).
Check that the servo amplifier and servo motor operate normally. With the servo motor disconnected from the machine, use
the test operation mode and check whether the servo motor operates correctly. This section describes how to check the servo
motor operation in the JOG operation. The test operation also includes the positioning operation and program operation.
Page 43 Test operation
In the linear servo motor control mode, the JOG operation cannot be performed. Check whether the motor operates correctly
using the positioning operation and others.
Page 44 Motor driving by test operation
1.
Turn off the power.
2.
Turn "ON (up)" the test operation select switch (SW3-1).
RUN
MS
ERR
NS
SFTY
3.
Turn on the power supply of the servo amplifier. Once initialization is complete, the display will change as follows.
Test operation status display
This figure shows the 1-axis servo amplifier.
4.
Open the JOG operation screen of MR Configurator2.
ON
1
2
Set SW3-1 to "ON (up)".
4 STARTUP
4.1 Switching power on for the first time
4
39