Duplicate Setting; Duplication Using Mr Configurator2; Test Operation; Execution Method - Mitsubishi Electric Melservo MR-J5-G Series User Manual

Hide thumbs Also See for Melservo MR-J5-G Series:
Table of Contents

Advertisement

4.4

Duplicate setting

The parameter of the servo amplifier of which the setting is completed can be copied to the other servo amplifier. Use this
function when replacing the servo amplifier of equipment with another servo amplifier during operation, and when starting up
multiple devices with the same configuration.
Restrictions
■The following data are not duplicated. Set them as required after the duplication.
Item
Homing
Mechanical life diagnosis
■The following data are not duplicated.
• Alarm history data
• Drive recorder data

Duplication using MR Configurator2

1.
The data set in MR Configurator2 can be saved as a project.
2.
To copy the project to a different servo amplifier, open the project and then connect the servo amplifier and a personal
computer via a USB cable. Switch on control circuit power supply of the servo amplifier.
3.
Write the required data in MR Configurator2. After the writing is completed, cycle the power or reset the software, as
necessary.
4.5

Test operation

Using the test operation function enables the machine operation to be checked before the actual operation. With a personal
computer and MR Configurator2, the JOG operation, positioning operation, output signal forced output, program operation,
and others can be used.
Precautions
• The test operation mode is designed for checking servo operation. It is not for checking machine operation. Do not use this
mode with the machine. Use the servo motor alone.

Execution method

Test operation mode is enabled by MR Configurator2. To set to the normal operation mode again after executing the test
operation mode, cycle the power or reset the software.
• Perform the test operation after the forced stop has been released. For details of the forced stop, refer to "Forced stop
deceleration function" in the following manual.
MR-J5 User's Manual (Function)
Description
The information of the home position is not duplicated. Execute homing again.
Mechanical life diagnosis information may not be duplicated. Refer to
"Machine diagnosis" in the following manual, and perform required settings.
MR-J5 User's Manual (Function)
4 STARTUP
43
4.4 Duplicate setting
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-j5w-g series

Table of Contents