Creating Custom Motor Files
B-11
Integral Thermostat
The integral thermostat check box should be checked if the motor has a built-in thermostat. If this box is
not checked, the thermostat inputs to the drive are ignored.
When the integral thermostat check box is selected, a motor overtemperature fault is displayed if the
thermostat inputs to the drive are in an open state.
Maximum Speed
This value specifies the maximum speed in RPM that the motor can safely maintain on a continuous basis.
The maximum speed value can be in the range from 0.00002 to 32767.99998 RPM.
Installation Manual for Models ODM-005, ODM-005i, ODM-010, ODM-010i, ODM-020 and ODM-020i