THOMSON Omnidrive Series Installation Manual page 112

Table of Contents

Advertisement

display codes.
2. Start OMNI LINK on the PC.
3. Choose Cancel from the Drive Select dialog box.
4. Select PC Set Up from the Communications menu in OMNI LINK to display the personal com-
puter's communication settings.
5. Verify the communications port settings of the PC match those of the drive.
If the settings are correct, select OK in the Port – Settings dialog box.
If the settings are different, correct the Port – Settings to allow communications with the
drive.
Factory default communications Port – Settings for the drive are:
– Baud Rate: 9600
– Data Bits: 8
– Parity: None
– Stop Bits: 1
– Serial Port: COM1
Refer to the section "RS-232 Communication Test" on page 11-6 for troubleshooting instructions.
6. Select Read Drive Parameters from the Communications menu.
7. Verify the Drive Name and Address are correct for the drive that is being addressed.
8. Choose OK to load the drive parameters.
A motor must be selected for the parameters to load.
TIP
9. If the message box appears that a motor must be selected, select OK. The Drive Setup window is
displayed with Motor Model selection parameter active. The motor may be selected from the
drop down box. If this message box does not appear, the motor displayed in the Motor Model
box was previously selected.
10. Select or verify the correct motor model number from the drop down Motor Model list.
11. If a message advises that the drive must be reset, choose Yes.
12. Select Indexing as the Operation Mode for the drive.
13. Choose Close to exit the Drive Set Up window.
14. Choose the Drive Parameters command icon from the Drive window and then select the
Indexing tab.
15. Enter the following values for Index 0. Refer to "Incremental Indexing Examples" on page 8-21
for examples of Single and Batched Incremental Indexing profiles.
Single Move Settings
Incremental
as Mode
8000
as Distance
1
as the Batch Count
0
as Dwell
Appropriate values for Acceleration and Decelera-
tion
Installation Manual for Models ODM-005, ODM-005i, ODM-010, ODM-010i, ODM-020 and ODM-020i
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Application and Configuration Examples
Batched Move Settings
Incremental as Mode
8000 as Distance
3
as the Batch Count
1000
as Dwell
Appropriate values for Acceleration and Decelera-
tion
8-23

Advertisement

Table of Contents
loading

Related Products for THOMSON Omnidrive Series

Table of Contents