THOMSON Omnidrive Series Installation Manual page 122

Table of Contents

Advertisement

7. Verify the Drive Name and Address are correct for the drive that is being addressed.
8. Choose OK to load the drive parameters.
A motor must be selected for the parameters to load.
TIP
9. If the message box appears that a motor must be selected, select OK. The Drive Setup window is
displayed with Motor Model selection parameter active. The motor may be selected from the
drop down box. If this message box does not appear, the motor displayed in the Motor Model
box was previously selected.
10. Select or verify the correct motor model number from the drop down Motor Model list.
11. If a message advises that the drive must be reset, choose Yes.
12. Select Indexing as the Operation Mode for the drive.
13. Choose Close to exit the Drive Set Up window.
14. Choose the Drive Parameters command icon from the Drive window and then select the
Indexing tab.
15. Select the following values for Index 0:
Absolute as Mode
8000 as Position
1 as Batch Count
0 as Dwell
Appropriate values for Velocity, Accelera-
tion and Deceleration
16. Choose Close to exit the Drive Parameters window.
17. Verify the Status indicator is green.
18. Select the I/O Configuration command icon from the Drive Window.
19. Select an appropriate digital input from the pull-down lists available as Digital Input Assign-
ments in the I/O Configuration window.
For example:
Start Index as Input 1.
Define Home as Input 2.
Not Assigned as Inputs 3.
Not Assigned as Outputs 1 through 2.
20. Choose Close to exit the I/O Configuration window.
Installation Manual for Models ODM-005, ODM-005i, ODM-010, ODM-010i, ODM-020 and ODM-020i
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Application and Configuration Examples
8-33