Heat Pump - DeDietrich EASYLIFE Alezio G AWHP 4.5MR–EMC 24/28 MI HYBRIDE User Manual

Hybrid heat pump
Table of Contents

Advertisement

3 Technical specifications
Tab.10
Other data
Alezio G hybrid
Boiler weight (empty)
Average acoustic level
(1)
from the boiler
(1) Maximum
Tab.11
Conditions of use
Limit water operating
temperatures in heating
mode
Outdoor air operating
temperature limits in
heating mode
Water operating temper­
ature limits in cooling
mode
Outdoor air operating
temperature limits in
cooling mode
Tab.12
Heating mode: outside air temperature +7°C, water temperature at the outlet +35°C. Performances in accordance with
EN 14511-2.
Measurement type
Heat output
Coefficient of perform­
ance (COP)
Absorbed electrical
power
Nominal water flow rate
(ΔT = 5 K)
Tab.13
Heating mode: outside air temperature +2 °C, water temperature at the outlet +35 °C. Performances in accordance
with EN 14511-2.
Measurement type
Heat output
Coefficient of perform­
ance (COP)
Absorbed electrical
power
18
at a distance of one metre
AWHP 4.5 MR
+18 °C/+55 °C
-15° C/+35 °C
+7°C / +25°C
+7 °C/ +46 °C
Unit
AWHP 4.5 MR
kW
4.6
5.11
kWe
0.90
0.80
3
m
/hour
Unit
AWHP 4.5 MR
kW
3.47
3.94
kWe
0.88
kg
Central heating
dB(A)
operation
DHW operation
3.2.2

Heat pump

Maximum operating pressure: 0.3 MPa (3 bar)
AWHP 6 MR-3
+18 °C/+60 °C
-15° C/+35 °C
+7°C / +25°C
+7 °C/ +46 °C
AWHP 6 MR-3
5.82
4.22
1.38
1.00
AWHP 6 MR-3
3.74
3.37
1.11
24/28 MI
34/39 MI
26
28.5
38
42
42
46
AWHP 8 MR-2
+18 °C/+60 °C
-20° C/+35 °C
+7°C / +25°C
+7 °C/ +46 °C
AWHP 8 MR-2
7.90
4.34
1.82
1.36
AWHP 8 MR-2
6.80
3.30
2.06
7611444 - v06 - 04032019

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents