Counters, Time Prog, Clock \Circa, Circb And Dhw Menus; Counters, Time Prog, Clock \Clk Menus - DeDietrich EASYLIFE Alezio G AWHP 4.5MR–EMC 24/28 MI HYBRIDE User Manual

Hybrid heat pump
Table of Contents

Advertisement

Parameter
Description
DC003
Number of hours during which the diverting valve
is in DHW position
DC004
Number of compressor start-ups during domestic
hot water production
DC005
Number of compressor start-ups
PC003
Number of compressor operating hours
CODE
Enter the installer code to access the following pa­
rameters.
AC002
Number of hours that the appliance has been
producing energy since last service
AC003
Number of hours since the previous servicing of
the appliance
AC004
Number of generator startings since the previous
servicing.
AC013
Seasonal coefficient of performance
SERVICE
Resetting the maintenance service
CLR: the AC002, AC003, and AC004 counters are
reset to zero.
Tab.30
Menu
CIRCA
CIRCB
DHW
Tab.31
CLK parameter
HOURS
MINUTE
DATE
MONTH
YEAR
7611444 - v06 - 04032019
6.3.2
COUNTERS, TIME PROG, CLOCK
and DHW menus
Description
TP.H: Timer programming for heating
06:00 - 23:00 ON
23:00 - 06:00 OFF
TP.C: Timer programming for cooling
14:00 - 23:00 ON
23:00 - 14:00 OFF
TP.H: Timer programming for heating
06:00 - 23:00 ON
23:00 - 06:00 OFF
TP.C: Timer programming for cooling
14:00 - 23:00 ON
23:00 - 14:00 OFF
Timer programming for domestic hot water
06:00 - 23:00 ON
23:00 - 06:00 OFF
6.3.3
COUNTERS, TIME PROG, CLOCK
Unit
Can be set from 0 to 23
Can be set from 0 to 59
Can be set from 1 to 31
Can be set from 1 to 12
Can be set from 2000 to 2100
Unit
EHC–04
hours
X
X
X
hours
X
X
hours
X
hours
X
X
X
X
HMI
available
available
available
available
available
6 Settings
SCB-04
\CIRCA, CIRCB
\CLK menus
37

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents