6 Settings
Parameter
Description
CP570
Time Program of the zone selected by the user
0 = programme 1
1 = programme 2
2 = programme 3
CP660
Choice icon to display this zone
0 =None
1 =All
2 =Bedroom
3 =Livingroom
4 =Study
5 =Outdoor
6 =Kitchen
7 =Basement
8 =Swimming Pool
Tab.22
Parameter
Description
DP060
Time program selected for DHW.
0 =Schedule 1
1 =Schedule 2
2 =Schedule 3
3 =Cooling
DP070
Comfort temperature setpoint from the Domestic Hot Water tank
Can be set from 40 °C to 65 °C
DP080
Reduced temperature setpoint from the Domestic Hot Water tank
Can be set from 10 °C to 60 °C
DP200
DHW primary mode current working setting
0 =Scheduling
1 =Manual
2 =Antifrost
3 =Temporary
DP337
Holiday temperature setpoint from the Domestic Hot Water tank
Can be set from 10 °C to 60 °C
Tab.23
Parameter
Description
AP015
Force manually the heat pump in cooling mode
0 =No
1 =Yes
AP016
Enable central heating heat demand processing
0= off (no heating or cooling)
1 = on
AP017
Enable domestic hot water heat demand processing
0 = off
1 = on
34
6.2.2

User \DHW menu

DP : Direct Hot Water Parameters = Domestic hot water tank parameters
6.2.3
User \EHC–04 menu
AP : Appliance Parameters = Appliance parameters
Factory setting
Factory setting
CIRCA
CIRCB
0
0
0
3
Factory setting
0
54
10
1
10 °C
Factory setting
0
1
1