Baumuller BUS 6-T Series Technical Description And Operations Manual page 97

Table of Contents

Advertisement

Encoder evaluation

incremental encoder emulation (with synchronous motors only)
Via this parameter the resolution of the incremental encoder emulation can be set, i.e. the
number of emulated increments per physical motor revolution. The permissible value
depends among other things on the respective operating status.
Value
0
1
2
3
4
5
6
7
Maximum resolution =
e.g. if the resolver resolution is set to 12 bit, the maximum resolution of the incremental
encoder emulation is only 1024 increments.

resolver resolution (with synchronous motors only)
This parameter specifies the resolution or speed-dependent dynamic switching between
different resolutions.
Value
0
1
2
3
4
5
6
7

resolver position correction (with synchronous motors only)
This parameter sets the zero position of the resolver evaluation to the motor's rotor position.

application speed for generator M reduction and flux controller P component
adaptation (with synchronous motors only))
This parameter selects the speed for the generator torque reduction and for the P adaptation
of the flux controller.
Controller BUS 6 T
Baumüller Nürnberg GmbH
Resolution
128 increments
256 increments
512 increments
1024 increments
2048 increments
4096 increments
8192 increments
16384 increments
Resolver resolution
4
Meaning
interlocks 16 bit resolution (n
act
interlocks 14 bit resolution (n
act
dynamic switching between 14 bit and 16 bit
interlocks 12 bit resolution (n
act
dynamic switching between 12 bit and 14 bit
dynamic switching between 12 bit, 14 bit and 16 bit
8192 increments
16384 increments
5.94017.06
< 500 rpm)
< 2500 rpm)
< 10000 rpm)
Parameters
91