Baumuller BUS 6-T Series Technical Description And Operations Manual page 108

Table of Contents

Advertisement

Maintenance

Manufacturer Class 1 Diagnostics
Display of drive interlocking. A Class 1 Diagnostics error situation detected by the drive
leads to:
controller inhibit with brake down or pulse inhibit
setting of error bit.
Bit no.
0
1
2
3 ... 7
8
9
10 ... 15
PI (pulse inhibit)
Delete the error bit (after remedying the fault) with the reset command (ID no. 99). When
switching on again a reset signal is automatically generated.

command "reset Class 1 Diagnostics"
If the drive receives this command via the service channel, Class 1 Diagnostics,
Manufacturer Class 1 Diagnostics and drive interlocking are deleted provided no more
errors are present.
The current error messages are deleted via the command
If an error in the BUG supply is present, the error must be deleted by switching the entire
supply voltage off and then on again (wait for the intermediate circuit capacitors to
discharge).
Additionally this command can be activated with digital input X22:3 (+24 V necessary).
Bit no.
0
1
2 ... 15
102
Meaning
1: operating error BUS (PI or CI)
1: hardware error BUS (PI)
1: software error BUS (PI)
reserved
1: operating error BUG supply (PI)
1: hardware error BUG supply (PI)
reserved
Meaning
0: delete command in drive
1: set command in drive
0: interrupt command execution
1: enable command execution
reserved
5.94017.06
Status messages
CI (controller inhibit)
 
and
Baumüller Nürnberg GmbH
 
.
Controller BUS 6 T

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents