Parameters
polarity of set torque value
Clockwise rotation of the motor shaft (seen from the front) takes place if the set torque value
and the polarity are positive.
Bit no.
0
1
2
3
4 ... 15
positive torque limit value
negative torque limit value
bipolar torque limit value
Display of torque limitation. With M control a value < 1 % should be set.
The torque limit values limit torque either in positive or negative direction or symmetrically.
With analog set value input (I/O option board 3.9211)
a) X2:7 = +10 V or -10 V
ID no. 82 = 100 %
ID no. 83 = -100 %
ID no. 92 = 100 %
b) X2:7 = +10 V
ID no. 82 = 100 %
ID no. 83 = 0 %
ID no. 92 = 100 %
c) X2:7 = -10 V
ID no. 82 = 0 %
ID no. 83 = -100 %
ID no. 92 = 100 %
On exceeding the torque limit value the drive sets the message in Class 3 Diagnostics.
actual torque value
This parameter displays the current actual torque value.
78
Meaning
set torque value
0: positive polarity
1: negative polarity
reserved
actual torque value
0: positive polarity
1: negative polarity
analog actual torque value
0: unipolar pos. and neg. actual torque value [0 ... +10V]
1: bipolar
pos. actual torque value (bit no. 2 = 0)
[0 ... +10V]
neg. actual torque value (bit no. 2 = 1)
[0 ... -10V]
on PCB 3.9211 between X3:5 und X3:6
reserved
X2:8 = 0 V
X2:8 = 0 V
X2:8 = 0 V
5.94017.06
Parameter set 0
ID no. 32926 = 0
ID no. 32926 = 1
ID no. 32926 = 1
Controller BUS 6 T
Baumüller Nürnberg GmbH