Basic settings
set magnetising current value (I
The magnetising current value is always 0 by synchronous motors.
magnetising current limitation (I
The maximum value of the magnetising current is entered via these parameters.
Sychronous motors:
Asynchronous motors:
set active current value (I
active current limitation (I
The active current limitation is entered via this parameter.
Asynchronous motors:
time constant of actual torque value
This parameter specifies the time constant of the actual torque value.
Typical value 1 ms ... 3 ms.
set apparent current value(I
apparent current limitation(I
This parameter displays the set value and the limitation of the apparent current.
torque controller gain
torque controller integral-action time
These parameters indicate the torque controller's gain and its integral-action time.
flux controller gain
flux controller integral-action time
These parameters specify the flux controller's gain and its integral-action time.
Controller BUS 6 T
Baumüller Nürnberg GmbH
)
α α α α N
)
α α α α G
typical value 5 A ... 20 A
1.2 x set magnetising current value (ID no. 32814)
)
β β β β N
=
2
−
2
I
I
I
β
α
N
N
N
)
β β β β G
1.2 x set active current value (ID no. 32804)
)
N
)
NG
5.94017.06
Parameters
59