Baumuller BUS 6-T Series Technical Description And Operations Manual page 104

Table of Contents

Advertisement

Parameters
Parameter overview
ID no.
spindle positioning
222
spindle positioning speed
57
positioning window
150
reference offset
Parameter description

spindle positioning speed
If the command "spindle positioning" is given, the drive either slows down to the spindle
positioning speed or retains the set speed.
If the command "spindle positioning from standstill" is given, the drive accelerates to the
spindle positioning speed.

positioning window
If the absolute value difference between final position value and actual position value
becomes smaller than the positioning window, this is signalled to the NC for continued
processing according to mode.
 
reference offset
This parameter describes the distance between the position encoder zero mark and
reference mark 1 (thus it is not necessary to mechanically turn the motor encoder to the
machine-specific zero mark).
98
Name
5.94017.06
Range
min. ... max.
0.0000 ... 1500.0000
0.0000 ... 6.500
-360.0000 ... +360.0000
Position control
Unit
Standard
Display
value
only
rpm
150.0
degree
degree
0.000
Controller BUS 6 T
Baumüller Nürnberg GmbH