Parameter set 0
Parameter overview
ID no.
velocity and ramp function generator
36
set velocity value
43
polarity of set velocity value
38
positive velocity limit value
39
negative velocity limit value
91
bipolar velocity limit value
40
actual velocity value
32825
ramp function generator
32826
ramp-up time
32827
ramp-down time
Parameter description

set velocity value
Set velocity value which can be set via the service PC. Switching of set value via
ID no. 32818.
Clockwise rotation of the motor shaft (seen from the front) takes place if the set velocity
value and the polarity are positive.
In the case of analog set value input this parameter serves for display purposes only.
Analog set value input (I/O option board 3.9211)
- MSP
- C axis
- additional n

polarity of set velocity value
This parameter corrects the polarity of the set/actual velocity value. Clockwise rotation of
the motor shaft (seen from the front) takes place if the set velocity value and the polarity are
positive.
Bit no.
0
1 ... 2
3
4 ... 15
Controller BUS 6 T
Baumüller Nürnberg GmbH
Name
-12000.0000 ... 12000.0000
-12000.0000 ... 12000.0000
(-10 V .. + 10 V)
(-10 V .. + 10 V)
(-10 V .. + 10 V)
set
set velocity value
0: positive polarity
1: negative polarity
reserved
analog actual velocity value
0: unipolar (clockwise and anti-clockwise speed [0 ... +10V]
1: bipolar
(clockwise speed [0 ... +10V]
anti-clockwise speed [0 ... -10V])
on PCB 3.9211 between X3:4 and X3:6
reserved
5.94017.06
Range
min. ... max.
0.0000 ... 12000.0000
0.0000 ... 12000.0000
0.0000 ... 12000.0000
0 ... 1
0.010 ... 60.000
0.010 ... 60.000
at X2:2 and X2:1
at X2:5 and X2:4
at X3:2 and X3:1
Meaning
Parameters
Unit
Standard
Display
value
only

(
)
rpm
0
0
rpm
rpm
rpm

rpm
0
s
0.01
s
0.01
75