Maintenance

boot initialisation error
If an error occurs during the controller's boot procedure this error bar is activated and
controller enabling is not possible (controller inhibit).
NOTE
This ID no. can only be read by activation of key F4 on PC. Only the LED´s „Power" (green)
and „controller inhibit" (red) light on the unit.
Bit no.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14 ... 15
106
Meaning
1: error data D502(D802) digital motherboard
1: error command data D502(D802) digital motherboard
1: error data D504 digital motherboard
1: error command data D504 digital motherboard
1: error data D503 digital motherboard
1: error command data D503 digital motherboard
1: error data D101 analog motherboard
1: error command data D101 analog motherboard
1: error data D102 analog motherboard
1: error command data D102 analog motherboard
1: error data D103 analog motherboard
1: error command data D103 analog motherboard
1: error data D104 analog motherboard
1: error command data D104 analog motherboard
reserved
5.94017.06
Status messages
Controller BUS 6 T