Status messages

BUS operating error
An operating error of the servo unit leads to pulse inhibit (PI) or controller inhibit (CI).
Bit no.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

BUS hardware error
According to the error type a hardware error of the servo unit either leads to pulse inhibit
(PI) or to controller inhibit (CI).
Bit no.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Controller BUS 6 T
Baumüller Nürnberg GmbH
Meaning
1: power unit ready for use (PI)
1: communication not enabled (PI)
1: power unit error (PI)
1: auxiliary voltage failure (PI)
1: excess current error (PI)
1: fault current (PI)
1: reference voltage error (PI)
1: overvoltage error (PI)
1: transistor error V1l BUS (PI)
1: transistor error V1u BUS (PI)
1: transistor error V2l BUS (PI)
1: transistor error V2u BUS (PI)
1: transistor error V3l BUS (PI)
1: transistor error V3u BUS (PI)
1: BUG ready for use (PI)
1: actual speed > limit speed (CI)
Meaning
1: error of internal RAM
1: error of external RAM
1: memory submodule EPROM not available
1: memory submodule EEPROM faulty
1: memory submodule EEPROM not available
1: timeout at upper A/D converter (CI)
1: timeout at lower A/D converter (CI)
1: offset error at upper A/D converter (CI)
1: offset error at lower A/D converter (CI)
1: error during power unit recognition (PI)
1: error during motor recognition (PI)
1: encoder module 1 not available (PI)
1: break of amplifier temperature sensor (CI)
1: break of circuitry housing temperature sensor (CI)
1: break of motor temperature sensor (CI)
1: initialisation error of I/O components (PI)