Speed Reference Via Digital Inputs - WEG CFW-11 Applications Manual

Crane horizontal motion
Hide thumbs Also See for CFW-11:
Table of Contents

Advertisement

Crane Horizontal Motion

2.1.2 Speed Reference via Digital Inputs

The control connections (analog inputs/outputs and digital inputs/outputs) wired at the CFW-11 electronic
control board CC11 terminal strip XC1, when the speed reference is through the logical combination of digital
inputs for 5 references, are presented next.
Figure 2.2 – Signals at the XC1 terminal strip for crane horizontal motion with speed reference via the logical
NOTE!
It is necessary to install the IOC-01 or IOC-02 accessory module in case the DI9, DI10, DI11 and
DI12 digital inputs and/or the DO6 and DO7 digital outputs use is required. Refer to the CFW-11
frequency inverter manual for more information on accessory modules.
XC1 Terminal
Strip
1
REF+
Positive reference for potentiometer
2
AI1+
Analog input # 1 (0 - 10 V): No function
3
AI1-
4
REF-
Negative reference for potentiometer
5
AI2+
Analog input # 2 (0 - 10 V): No function
6
AI2-
7
AO1
Analog output # 1: Motor speed
8
AGND
9
AO2
Analog output # 2: Motor current
10
AGND
11
DGND
Reference (0 V) for the 24 Vdc power supply
12
COM
Common point of the digital inputs
13
24VCC
24 Vdc power supply
14
COM
Common point of the digital inputs
15
DI1
Digital input # 1: Load forward command
16
DI2
Digital input # 2: Load reverse command
17
DI3
Digital input # 3: Emergency stop
18
DI4
Digital input # 4: 1st DI for speed reference
19
DI5
Digital input # 5: 2nd DI for speed reference
20
DI6
Digital input # 6: 3rd DI for speed reference
21
NC1
22
C1
Digital output #1 DO1 (RL1): No fault
23
NO1
24
NC2
25
C2
Digital output #2 DO2 (RL2): Run
26
NO2
27
NC3
28
C3
Digital output #3 DO3 (RL3): Brake release
29
NO3
combination of digital inputs
Default Function for Speed Reference via Digital Inputs
Crane Horizontal Motion | 16