Parameters Description
P1050 – Time to Enable a new Command to Brake Release
Adjustable
0.10 to 650.00 s
Range:
Proprieties:
Access groups via HMI:
Description:
This parameter defines a time after the command to brake closing has been executed via the digital output of
the CFW-11, so that a new command to load forward or load reverse is accepted and thus the brake can be
released again thus preventing a new command to be generated without the brake being closed mechanically.
NOTE!
The value of the set time should be sufficient to ensure that a new command to load forward or load
reverse performs with the brake closed, but that does not generate a very large delay in the crane
operation.
NOTE!
Refer to the section 2.2 in this application manual for more information on the connection diagram
and brake power supply.
01 PARAMETER GROUPS
∟ 50 SoftPLC
Factory Setting:
.....
Crane Horizontal Motion | 42
0.20 s