Parameters Description
P1050 – Time to Enable a new Command to Brake Release
Adjustable
0.10 to 650.00 s
Range:
Proprieties:
Access groups via HMI:
Description:
This parameter defines a time after the command to brake closing has been executed via the digital output of
the CFW-11, so that a new command to load forward or load reverse is accepted and thus the brake can be
released again thus preventing a new command to be generated without the brake being closed mechanically.
NOTE!
The value of the set time should be sufficient to ensure that a new command to load forward or load
reverse performs with the brake closed, but that does not generate a very large delay in the crane
operation.
NOTE!
Refer to the section 2.2 in this application manual for more information on the connection diagram
and brake power supply.