WEG CFW-11 Applications Manual page 28

Crane horizontal motion
Hide thumbs Also See for CFW-11:
Table of Contents

Advertisement

Parameters Description
P1034 – Speed Reference 4
Adjustable
0.0 to 1020.0 Hz
Range:
Proprieties:
Access groups via HMI:
Description:
This parameter has different functions according to the speed reference control configuration:
P1023 = 0, 1, 2, 3, 6 or 7, the parameter does not have a specific function for the crane horizontal motion
applicative.
P1023 = 4 or 5, it defines the value of the 4th speed reference for the crane horizontal motion applicative.
P1035 – Speed Reference 5
Adjustable
0.0 to 1020.0 Hz
Range:
Proprieties:
Access groups via HMI:
Description:
This parameter has different functions according to the speed reference control configuration:
P1023 = 0, 1, 2, 3, 4, 6 or 7, the parameter does not have a specific function for the crane horizontal motion
applicative.
P1023 = 5, it defines the value of the 5th speed reference for the crane horizontal motion applicative.
P1036 – Dwell Time at Speed Reference 1
Adjustable
0.00 a 650.00 s
Range:
Proprieties:
Access groups via HMI:
Description:
This parameter defines the crane dwell time with the speed reference 1 after the brake release. I.e., maintains
the speed reference 1 for a while even if another speed has been selected by the user.
01 PARAMETER GROUPS
∟ 50 SoftPLC
01 PARAMETER GROUPS
∟ 50 SoftPLC
01 PARAMETER GROUPS
∟ 50 SoftPLC
Factory Setting:
P1023 = 0: 0.0 Hz
P1023 = 1: 0.0 Hz
P1023 = 2: 0.0 Hz
P1023 = 3: 0.0 Hz
P1023 = 4: 60.0 Hz
P1023 = 5: 45.0 Hz
P1023 = 6: 0.0 Hz
P1023 = 7: 0.0 Hz
.....
Factory Setting:
P1023 = 0: 0.0 Hz
P1023 = 1: 0.0 Hz
P1023 = 2: 0.0 Hz
P1023 = 3: 0.0 Hz
P1023 = 4: 0.0 Hz
P1023 = 5: 60.0 Hz
P1023 = 6: 0.0 Hz
P1023 = 7: 0.0 Hz
.....
Factory Setting:
.....
Crane Horizontal Motion | 28
0.50 s

Advertisement

Table of Contents
loading

Table of Contents