WEG CFW-11 Applications Manual page 52

Crane horizontal motion
Hide thumbs Also See for CFW-11:
Table of Contents

Advertisement

Parameters Description
Bit 8
0: No load reverse command
Load Reverse
1: It indicates that a load reverse command is being executed.
Command
Bit 9
0: It indicates that a brake closing command is being executed.
Brake Release
1: It indicates that a brake release command is being executed.
Command
Bits 10 to 15
Reserved.
P1021 – Crane Horizontal Motion Status Word 2
Adjustable
0000h to FFFFh
Range:
Proprieties:
RO
Access groups via HMI:
Description:
This parameter allows the monitoring of the present alarm and fault condition in the crane horizontal motion
application. Each bit represents one specific status.
Bits
15
14
Function
Bits
Bit 0
0: No alarm indication
Lightweight Operation
1: It indicates that the crane horizontal motion is in the lightweight operation mode (A750).
Bit 1
0: No alarm indication
Coast to Stop
1: The general enable signal has been removed from the DI3 causing the motor to cast down (A752).
Bit 2
0: No alarm indication
Fast Stop
1: It indicates that a fast stop via digital input DI3 has been executed (A754).
Bit 3
0: No alarm indication
Emergency Stop
1: It indicates that an emergency stop via digital input DI3 has been executed (A756).
Bit 4
0: No alarm indication
Stop by Simultaneous
1: It indicates that a stop occurred because of simultaneous forward and reverse commands (A758).
Commands
Bit 5
0: No alarm indication
Forward Slowdown
1: It indicates that the forward slowdown limit switch has been actuated (A760).
Bit 6
0: No alarm indication
Reverse Slowdown
1: It indicates that the reverse slowdown limit switch has been actuated (A762).
Bit 7
0: No alarm indication
Stop Forward
1: It indicates that the stop forward limit switch has been actuated (A764).
Bit 7
0: No alarm indication
Stop Reverse
1: It indicates that the stop reverse limit switch has been actuated (A766).
Bit 9
0: No alarm indication
Momentary Overload
1: It indicates that the momentary overload condition has been detected during the forward or reverse stage
Alarm
(A770).
Bit 10
Reserved
Bit 11
Reserved
Bit 12
0: No fault indication
Inverter in Torque Limit
1: It indicates that the inverter in torque limit condition has been detected (F775).
Bit 13
0: No fault indication
Improper Operation
1: It indicates that the improper operation condition has been detected (F777).
Bit 14
Reserved
Bit 15
Reserved
01 PARAMETER GROUPS
∟ 50 SoftPLC
Table 3.5 – Status word 2 description
13
12
11
10
.....
9
8
7
6
Values
Factory Setting:
5
4
3
2
Crane Horizontal Motion | 52
-
1
0

Advertisement

Table of Contents
loading