Analog Input - WEG CFW-11 Applications Manual

Crane horizontal motion
Hide thumbs Also See for CFW-11:
Table of Contents

Advertisement

Parameters Description
NOTE!
Refer to the section 3.13 in this application manual for more information on the momentary overload
detection logic.
DO7 Function
Description:
It is an IOC-01 or IOC-02 accessory module digital output with exclusive SoftPLC function use, not presenting a
parameter for its configuration. It has the function of indicating the fault "F775: Inverter in Torque Limit".
NOTE!
Refer to the section 3.14 in this application manual for more information on the inverter torque limit
detection logic.
NOTE!
Refer to the IOC-01 or IOC-02 accessory module installation, configuration and operation guide for
more information on the DO6 and DO7 digital outputs.

3.10 ANALOG INPUT

This parameter group allows the user to configure the analog input AI1 for the speed reference control of the
crane horizontal motion.
NOTA!
It is configured only when the parameter P1023 (speed reference control configuration) is
programmed with the option 6.
P0231 – AI1 Signal Function
Adjustable
7 = Speed Reference (PLC Use)
Range:
Proprieties:
Access groups via HMI:
Description:
This parameter defines that the function of the analog input AI1 will be the crane horizontal motion speed
reference.
P0233 – AI1 Signal Type
Adjustable
0 = 0 to 10 V / 20 mA
Range:
1 = 4 to 20 mA
Proprieties:
Access groups via HMI:
Description:
This parameter configures the type of signal (voltage or current) that will be read by the analog input AI1. Adjust
the CFW-11 control board DIP switch S1.4 according to the selected option.
01 PARAMETER GROUPS
∟ 38 Analog Inputs
01 PARAMETER GROUPS
∟ 38 Analog Inputs
Factory Setting:
or
07 I/O CONFIGURATION
.....
∟ 38 Analog Inputs
Factory Setting:
or
07 I/O CONFIGURATION
∟ 38 Analog Inputs
.....
Crane Horizontal Motion | 36