Outlet: heating connection
Connection
via a contactor
An outlet is a dry contact and does not supply any voltage.
1 - Connect the cables in accordance with the chosen diagram.
2 - Start the secured Install menu (from the main menu, simultaneously hold down Esc and Valid for 3 secs. A star appears
in the top right corner of the home screen).
3 - On the Outlets / S1-S2-S3 sub-menu (in accordance with chosen terminal), select HEATING PUMP to indicate that a
heating pump (any kind) has been connected to the corresponding outlet.
4 - Via Temperature menu > Heating pump :
> Select OFF to cut off the heating pump.
> Select AUTO to ensure that the temperature is controlled automatically. A menu Setpoint will then appear. > Select
Setpoints to change the target value. A menu Priority will then appear. > Select Priority to activate or not. The priority will
activate the filtration and heating pump, even if filtration has been stopped. Do not activate the priority when the heating pump
has been activated, unless the filtration is running for another reason.
5 - Via Temperature menu > Calibration : Manual correction of the temperature concerned. Enables adjustment of temperature,
using another thermometer as a reference.
6 - Via Temperature menu > Anti freeze : Temperature where filtration is forced to prevent the pool from freezing. The heating
pump is not used for anti freeze protection.
- H eati n g p um p
Cal i b rati o n
Anti fre eze : + 3 °C
20
NEUTRAL (N)
A1
A2
EARTH
PHASE (L)
-Heati ng pump: AUTO
VALID
S et poi nt : 30° C
Pr i or i t y
: NO
Connection
via the safety shutdown
(flow switch)
CALIBRATION
-Temp. Water:+23.2°C
VALID
-Temp. Air :+23.3°C