Outlet: solar heating connection
An outlet is a dry contact and
does not supply any voltage.
12V
1 - Connect the cables in accordance with the diagram.
2 - Start the secured Install menu (from the main menu, simultaneously hold down Esc and Valid for 3 secs. A star appears
in the top right corner of the home screen).
3 - On the Inlets / E2 sub-menu, select Solar T° to indicate that the SB-PD-PRO-004B temperature sensor is connected to the
corresponding inlet.
4 - On the Outlets / S1-S2-S3 sub-menu (in accordance with chosen terminal), select SOLAR to indicate that a solar heater is
connected to the corresponding outlet.
5 - On the Temperature / Solar sub-menu, configure the settings:
-Solar : AUTO
Temp di erence :4°C
Delta heating :-2°C
Current T°
of pool water
N
L
230 V ~
AUTO: Activates solar heating and uses all available calories.
Temp difference: Difference between solar T°/pool T° which activates the solar heating.
Delta heating: Decreases T° set point for non-solar heating, so that solar heating can be the
primary type used.
Preferred T°
for solar power
Temp. di erence
Solar T°
SB-PD-PRO-004B
Set point T° for
Delta heating
Speedeo heating
Current T°
of solar probe