Access to restricted access mode 'Install'
SPEEDEO controls the equipment in the technical room, and the wrong settings may have serious
consequences for the safety of the pool. Because of this, access to certain initial configuration
functions is reserved for professionals, or people whose experience enables them to modify these
SPEEDEO
®
VA R I A B L E
S P E E D
0 1 : 0 3 Wa t e r : + 2 4 . 3 ° C *
Fi l t r a t i o n : V 2
S 1 : O F F S 2 : O N
S 3 : O F F
A I R : + 2 5 . 9 ° C
ESC
Menu organisation / Heating menu / Information menu
16:03 Water:+26.3°C
*
Filtration: ON
RedOx: 061mV
Air:+25.0°C pH: 7.2
- M o de : Cal i for ni a n
Choice between the 14
lighting modes
-He ati ng pu m p
Ca l i b rat i o n
Anti free ze : + 3 ° C
Below this temperature, the filtration runs 24/7 to prevent the pool from freezing (active wintering).
- If the air temperature probe is connected: it becomes the reference value for freeze protection management. Place it
outdoors, out of direct sunlight so that the measurements are not distorted (see p06). - If the air temperature probe is not
connected: the water temperature becomes the reference value for freeze protection management. Please check that the
technical room is not heated or has a significantly different temperature in comparison with the temperature outside. If this is
the case, the difference must be compensated by Calibration.
parameters while being fully aware of the consequences. In
order to limit accidental access, the Install menu menu has
secured access. (from the main menu, simultaneously hold
P U M P
down Esc and Valid for 3 secs. A star appears in the top right
corner of the home screen).
VALID
*
-Filtration length
Filtration speed
Filter washing
Inputs
Outputs
-Setting the time
Temperatures
Information
Languages
Update
Radio
Lighting
-L ANG UAGE : Fren ch
Choice between French
and English
- Heati n g pu mp: AU TO
S et po int : 30° C
Pr i o r it y
: N O
CALIBRATION
-Temp. Water : +23.2°C
-Temp. Air : +23.3°C
The Install menu menu is active.
It automatically deactivates after 15 mins of inactivity.
See p12-13 (this menu is not available if a SOLEO is linked)
See p11
See p17-18
See p14 (accessible via Install)
See p15 (accessible via Install)
See 13 (this menu is not available if a SOLEO is linked)
See p19 (accessible via Install)
See p10
AUTO Activate the heating pump until the set point value has
been reached. Priority: NO Make sure the heating pump
does not start until the filtration is already running. Priority:
YES Start filtration so that the heating can function.
This setting makes it possible to deliberately correct any
difference with another reference thermometer.
SPEEDEO v2
Version : 2.0
pentairpooleurope.com
Information about the
OS version
15