Outlet: Connections For A Controller And An Intellichlor P; 01:03 Water:+24.3°C Filtration: V2; S1:Off S2:On S3:Off Air:+25.9°C Intflo - Pentair SPEEDEO SB-PF-SPO-003C Installation And User Manual

Table of Contents

Advertisement

Outlet: control connection (chlorine or pH)
N
L
230 V ~
An outlet is a dry contact and does not supply any voltage.
1 - Connect the cables in accordance with the diagram.
2 - Start the secured Install menu (from the main menu, simultaneously hold down Esc and Valid for 3 secs. A star appears
in the top right corner of the home screen).
3 - On the Outlets / S1-S2-S3 sub-menu (in accordance with chosen terminal), select CONTROL to indicate that a control (any
kind) has been connected to the corresponding outlet.
This contact is closed (active outlet) while the filtration is running, whatever the rotation speed. The connected control is
guaranteed to function while the filtration pump is running.
PENTAIR IntelliChlor: Connections and functions
Connect the pump to the 230 V, connect to the 10-m long IntelliFlo cable (ref 350122), the green/yel-
low to the 'BUS', adhering to the colours.
Communication
for IntelliChlor ®
NEUTRAL (N)
PHASE (L)
1 - Connect the cables in accordance with the diagram.
2 - At the Home screen, wait for a few seconds and the indication for IntChl will appear.
centre
1
2
3
4
692
VA R I A B L E
S P E E D
01:03 Water:+24.3°C
Filtration: V2
S1:OFF S2:ON S3:OFF
AIR:+25.9°C IntChl
P U M P
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Speedeo sb-se-tec-006a

Table of Contents