Connection Of Intelliflo To Intellibus And Other Pumps With Variable Speeds P - Pentair SPEEDEO SB-PF-SPO-003C Installation And User Manual

Table of Contents

Advertisement

PENTAIR IntelliFlo: Connections and functions
Connect the pump to the 230 V, connect to the 10-m long IntelliFlo cable (ref 350122), the green/yellow to the
'BUS', adhering to the colours.
PHASE (L)
EARTH
NEUTRAL (N)
PENTAIR VS1 (Superflo, Ultraflow, SuperMax and S5P2R): Connections
and functions
Control the speeds S1 < S2 < S3 < S4 and S4 at 100% on the pump drive.
Set the DIP switches 1, 2, 3, 4 on the pump drive to ON.
1 - Connect the cables in accordance with the diagram.
2 - Start the secured Install menu (on the main menu, press Esc and Valid at the same time for 3 secs. A star
PENTAIR VS2 (Superflo, SuperMax, Ultraflow, S5P2R, Challenger and
Whisperflo): Connections and functions
Control the speeds S1 < S2 < S3 < S4 and S4 at 100% on the pump drive.
VA R I A B L E
+12
A
B
COM
STEP 1
STEP 2
STEP 3
OVRD
ICOM
S P E E D
P U M P
ON
1 2 3 4 5
11