Outlet: Connections For Lighting And A 3-Way Motorised Valve P - Pentair SPEEDEO SB-PF-SPO-003C Installation And User Manual

Table of Contents

Advertisement

Outlet: connection for lighting below 1,600 W
An outlet is a dry contact and does not
supply any voltage.
1 - Connect the cables in accordance with the diagram.
2 - Start the secured Install menu (from the main menu, simultaneously hold down Esc and Valid for 3 secs. A star appears
in the top right corner of the home screen).
3 - On the Inlets / E1 sub-menu, select LIGHTING to indicate that a dry contact has been connected to the corresponding inlet.
4 - For IntelliBrite and other LED lights with colours that may change with impulses,
on the Home menu, select Lighting and validate the chosen light programme type:
Outlet: connection for a 3-way motorised valve (OTHER)
N
L
230 V ~
A1
DIRECTION 1
DIRECTION 2
NEUTRAL (N)
22
< 1600 W
PHASE (L)
A2
EARTH
NEUTRAL (N)
N
L
230 V ~
PHASE (L)
NEUTRAL (N)
-M ode : Cal ifo r nia n
1 - Connect the cables in accordance with the diagram.
2 - Start the secured Install menu (from the main menu,
simultaneously hold down Esc and Valid for 3 secs. A star
appears in the top right corner of the home screen).
3 - On the Outlets / S1-S2-S3 sub-menu (in accordance with
chosen terminal), select OTHER to indicate that a motorised
valve is connected to the corresponding outlet.
An outlet is a dry contact and does not supply any
voltage.