Inlet: Connection For The End Of A Cover Line / Switch Or Remote Control P - Pentair SPEEDEO SB-PF-SPO-003C Installation And User Manual

Table of Contents

Advertisement

Inlet: connection for the end of a cover line
N
L
230 V ~
1 - Connect the cables in accordance with the diagram.
2 - Start the secured Install menu (from the main menu, simultaneously hold down Esc and Valid for 3 secs. A star appears
in the top right corner of the home screen).
3 - On the Inlets / E1-E2 sub-menu (in accordance with chosen terminal), select COVER CONTACT to indicate that a limit
contact has been connected to the corresponding inlet.
4 - On the Filtration Length / Cover Open sub-menu, select YES so that filtration is carried out while the cover is open (the
cover does not cover the pool). This is the primary function of the Filtration Length / Start setting (despite the setting of an
hour from the start and/or end of filtration, if the cover does not cover the pool all day, filtration will run all day).
5 - On the Filtration Speed / Events / Cover Open sub-menu, select YES so that the filtration speed changes from S1 to S2.
Inlet: connection for a switch, a remote control...
It is possible to connect any type of dry contact inlet (switch, remote control, relay) which activates an
outlet.
N
L
230 V ~
1 - Connect the cables in accordance with the diagram.
2 - Start the secured Install menu (from the main menu, simultaneously hold down Esc and Valid for 3 secs. A star appears
in the top right corner of the home screen).
3 - On the Inlets / E1-E2 sub-menu (in accordance with chosen terminal), select OTHER to indicate that a dry contact has been
connected to the corresponding inlet.
Inlet: connection for an air temperature probe (see p06)
18
The contact is closed when the cover is covering the pool