Menu: Filtration Length / Auto/On/Off/Timer/Shock Mode
- Once the SPEEDEO is linked to a SOLEO, this menu Filtration Length disappears. The
SOLEO will manage the filtration length.
Home menu > Filtration Length menu:
-Fi l trat io n : ON
Sta r t
: 0 5 :00
Sto p
: AUTO
m ode
: TURBO
This menu gives you control of the filtration start and end time, to control the level of noise linked to your pool (filtration noise),
for the sake of the neighbourhood. By default, leave End on AUTO.
In AUTO, SPEEDEO calculates the filtration end time.
Filtration speed menu
In AUTO, these events which adjust the different rotation
speeds for the pumps with variable speeds. The field for
Events will appear.
Home menu > Filtration Length menu:
S 2 t im e r : YE S
St ar t
: 1 1:0 0
E nd
: 1 6 :00
S 3 t im e r : YE S
St ar t
: 1 7:0 0
E nd
: 1 8 :00
Cover o p e n : NO
H e ati ng
: NO
S 3 i nl e t 1 : YE S
Time set menu
- Once the SPEEDEO is linked to a SOLEO, this menu Setting the time disappears. The SOLEO
will manage the time settings.
- H o u r : 1 6 h
M i n u te : 0 3 m i n .
Select current mode:
AUTO = Automatically calculates the filtration length according to the water
temperature.
ON = Filtration runs 24/7.
OFF = Filtration stops
TIMER = Filtration runs during the selected time period (see below)
CHOC = Activates 24-hour filtration. This function can be useful after the pool
has been used by many visitors and when the pool temperature is high. At the
end of the mode CHOC, SPEEDEO returns to normal AUTO.
- M ode: AU TO
Events
Event creation:
S2 timer = If YES the pump is running at S2 from the Start time to End.
S3 timer = If YES the pump is running at S3 from the Start time to End.
Cover open = Opening the cover (if connected) changes the speed from
S1 to S2.
Heating = Starting the heating pump (see p13) activates S2.
Inlet 1 S3 = Closing a contact at Inlet 1 starts S3 (e.g. connecting a switch
for activating a waterfall, an animation, swimming against the current...).
Makes it possible to set the time of the device. If the power supply is interrupted for more
than 30 min., reinstalling the time is necessary.
(note - anti freeze mode becomes
MANUAL displays the field Speed which enables
manual selection of the rotation speed for the pumps
with variable speeds.
- M ode : MA N UA L
S pe e d : S 2
inactive).