Cycle Time Calculation; Injector Flow Rates - Pentair AUTOTROL MAGNUM 293 Installer Manual

Table of Contents

Advertisement

Media
(35.6 cm)
Multi Layer
2
(15 gpm/ft
)
2
(36.75 m/h/cm
)
Birm, Greensand,
Carbon
2
(10 gpm/ft
)
2
(24.5 m/h/cm
)
* 10°C water temperature, 50% bed expansion.
4.2

Cycle time calculation

All the Logix controller range automatically calculates the unit capacity as well as the cycle time.
No calculations are therefore required.
4.3

Injector flow rates

The following graphs represent the injectors flow rate as a function of the inlet pressure for the
different injector sizes.
Ref. MKT-IM-012 / D - 03.02.2022
Installer manual Autotrol Magnum 293 - 298 Logix 742-762 - System sizing
14"
16"
(40.6 cm)
(45.7 cm)
Tank
Tank
15
20
10
15
Tank diameter
18"
21"
(53.3 cm)
(61.0 cm)
Tank
Tank
25
36
17
25
24"
30"
(76.2 cm)
(91.4 cm)
Tank
Tank
50
70
30
50
36"
Tank
105
70
31 / 110