■Error indication

Error name
Instantaneous flow
error
OUT1 over current
error
OUT2 over current
error
System error
Accumulated flow
Accumulated flow
error
Accumulated flow
: If the error cannot be reset after the above measures are taken, then please contact SMC.
Error display
The flow has exceeded the upper limit of
the flow display range.
Fluid is flowing in the reverse direction
by at least -5% of the maximum rated
flow value.
The switch output (OUT1) load current
has exceeded 80 mA.
The switch output (OUT2) load current
has exceeded 80 mA.
An internal data error has occurred.
The accumulated flow has exceeded the
accumulated flow range.
(For accumulated increment)
is displayed
(Flashing)
The accumulated flow has reached the
set accumulated flow value.
is displayed
(For accumulated decrement)
(Flashing)
Description
-65-
Measures
Reduce the flow.
Connect the fluid flow in the
correct direction.
Turn the power OFF and
remove the cause of the over
current. Then turn the power
ON again.
Turn the power OFF and turn
it ON again.
Reset the accumulated flow.
(Press the
and
buttons simultaneously for 1
second or longer) (page 58)