SMC Networks PF2A5 Series Operation Manual

Digital flow switch (remote type sensor unit)

Advertisement

Quick Links

No.PF※※-OMO0010-C
PRODUCT NAME
Digital Flow Switch
(Remote type sensor unit)
MODEL / Series / Product Number
PF2A5##

Advertisement

Table of Contents
loading

Summary of Contents for SMC Networks PF2A5 Series

  • Page 1 No.PF※※-OMO0010-C PRODUCT NAME Digital Flow Switch (Remote type sensor unit) MODEL / Series / Product Number PF2A5##...
  • Page 2: Table Of Contents

    Table of Contents Safety Instructions Model Indication and How to Order Summary of Product parts Definition and terminology Mounting and Installation Installation Piping Wiring Troubleshooting Cross-reference for troubleshooting Specification Specifications Characteristics data Dimensions No.PF※※-OMO0010-C...
  • Page 3: Safety Instructions

    Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger". They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)*1), and other safety regulations .
  • Page 4 Safety Instructions Caution 1.The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
  • Page 5 Operator This operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment. Only those persons are allowed to perform assembly, operation and maintenance. Read and understand this operation manual carefully before assembling, operating or providing maintenance to the product.
  • Page 6 Caution ■Do not touch the terminals and connectors while the power is on. Otherwise electric shock, malfunction or damage to the product can result. ■After maintenance is complete, perform appropriate functional inspections and leak tests. Stop operation if the equipment does not function properly or there is a leakage of fluid. When leakage occurs from parts other than the piping, the product might be faulty.
  • Page 7 ●Product handling Installation Tighten to the specified tightening torque. If the tightening torque is exceeded the mounting screws and brackets may damaged. If the tightening torque is insufficient, the product may be displaced and the mounting screws may come loose. ”Mounting and Installation”.) (Refer to page Ensure that the FG terminal is connected to ground when using a commercially available switch-mode...
  • Page 8 Wiring Do not pull the lead wires. In particular, never lift a product equipped with fitting and piping by holding the lead wires. Otherwise damage to the internal parts can result, causing malfunction or disconnection of the connector. Avoid repeatedly bending or stretching the lead wire, or placing heavy loads on it. Repeated bending stress or tensile stress can cause damage to the sheath, or breakage of the wires.
  • Page 9 Environment Do not use the product in an environment that is constantly exposed to the splash of water. Otherwise failure or malfunction can result. Take measures such as using a cover. Do not use the product in an environment where corrosive gases or fluids could be splashed. Otherwise damage to the product and malfunction can result.
  • Page 10 Adjustment and Operation Connect load before turning on the power. Supply the power when there is no flow. If using the product to detect very small flow rates, warm up the product for 10 to 15 minutes first. There will be a drift on the analogue output of approximate 2 to 3% immediately after the power supply is turn on, within 10 minutes.
  • Page 11: Model Indication And How To Order

    Model indication and How to Order -10- No.PF※※-OMO0010-C...
  • Page 12 Lead wire with lead wire and connector without lead wire (Straight, 3 m) : Lead wire is not assembled with the product, but shipped together. Connector without connector with sensor connector (1 pc.) : Connector is not assembled with the lead wire, but shipped together. Accessories/Part number If an accessory is required separately, order using the following part numbers.
  • Page 13: Summary Of Product Parts

    Summary of Product parts Connector pin numbers (on the product) DC(+) N.C./Analogue output DC(-) Output for PF2A3 Item Description Lead wire and connector Lead wire to supply power and transmit output signals. Connector Connector for electrical connections. Piping port Connected to the fluid inlet at IN and to the fluid outlet at OUT. Bracket Bracket for mounting the product.
  • Page 14: Definition And Terminology

    ■Definition and terminology Terms Meaning A type of variable output that has a value proportional to the measured quantity. When Analogue output the analogue output is in the range of 1 to 5 V or 4 to 20 mA, it will vary continuously, following the change of flow Attachment A metal part on both sides of the product to connect piping.
  • Page 15: Mounting And Installation

    Mounting and Installation ■Installation Never mount the product in a location that will be used as a foothold. ●Installing Install the product (with bracket) using the M4 screws (4 pcs.). Bracket thickness is approximately 1.6 mm. Refer to the dimension drawing of the bracket (page 25) for mounting hole dimensions. -14- No.PF※※-OMO0010-C...
  • Page 16: Piping

    ■Piping Use the product within the specified operating pressure range and temperature range. Proof pressure is 1.0 MPa. Connect the piping to the fittings. Mount the product so that the fluid direction is the same as the arrow indicated on the product. Never mount the product upside down.
  • Page 17: Wiring

    ■Wiring Connections should only be made with the power supply turned off. Use separate routes for the product wiring and any power or high voltage wiring. Otherwise, malfunction may result due to noise. Ensure that the FG terminal is connected to ground when using a commercially available switch-mode power supply.
  • Page 18 Attaching the sensor connector to the lead wire (When the product connects to the PF2A2 Refer to the PF2A2 operation manual for details of the sensor connector pin numbers. Strip the lead wire as shown. Do not cut the insulator. Insert the corresponding wire colour into the pin number printed on the sensor connector, to the bottom, then part A shown should be pressed in by hand to make temporary connection.
  • Page 19 ●Internal circuit and wiring example When the lead wire and connector designated for the PF2A5 is used, the wire colours will apply as shown in the diagram. Output for PF2A3 type PF2A5 Output impedance: 1 kΩ 1: Refer to the PF2A3 operation manual for details of the flow monitor.
  • Page 20 Output for PF2A3 + Analogue (4 to 20 mA) type PF2A5 Analogue output: 4 to 20 mA Load impedance: 300 Ω (12 VDC) 600 Ω (24 VDC) 1: Refer to the PF2A3 operation manual for details of the flow monitor. 3: Load indicates analogue input equipment such as an ammeter.
  • Page 21: Troubleshooting

    Troubleshooting Troubleshooting If an operation failure occurs with the product, use the chart below to find out the cause of the problem. If none of the countermeasures seem to be applicable, or a replacement product operates normally when installed, the product may be faulty. A product can be damaged by the operating environment (system configuration etc).
  • Page 22: Specification

    Specification ■Specifications Specifications of body Model PF2A510 PF2A550 PF2A511 PF2A521 PF2A551 Applicable fluid Air and N 0 to 50 C (no condensation or freezing) Fluid temperature 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 Rated flow range L/min L/min...
  • Page 23: Characteristics Data

    ■Characteristics data ●Flow characteristics (pressure loss) Model Graph a(L/min) b(L/min) PF2A510 PF2A550 PF2A511 PF2A521 PF2A551 ●Analogue output Voltage output Current output 4 mA 20 mA Rated flow range [L/min] Model Min. Max. PF2A510 PF2A550 PF2A511 PF2A521 PF2A551 -22- No.PF※※-OMO0010-C...
  • Page 24: Dimensions

    ■Dimensions (in mm) PF2A510/550 Output specifications Output for PF2A3 48 mm 62 mm 94.3 mm + Analogue output Output for PF2A3 58 mm 72 mm 104.3 mm -23- No.PF※※-OMO0010-C...
  • Page 25 PF2A511/521/551 Output specifications Output for PF2A3 48 mm 62 mm 94.3 mm + Analogue output Output for PF2A3 58 mm 72 mm 104.3 mm -24- No.PF※※-OMO0010-C...
  • Page 26 Lead wire and connector (Straight): ZS-37-A Lead wire and connector (Angle): ZS-37-B Bracket: ZS-29-T -25- No.PF※※-OMO0010-C...
  • Page 27 Revision history A: Revision. B: Contents revised in several places. C: Contents revised in several places. [July 2018] 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. ©...