Emulator Interface - Fujitsu MB91460 Getting Started

Emulation system
Hide thumbs Also See for MB91460:
Table of Contents

Advertisement

5.1.2 Emulator Interface

The emulator interface can be terminated if the in-circuit-emulator (ICE) is not used.
Jumper
S14
USER – INITX
INITX
INITX – ICE
S15
USER – TRSTX
TRSTX
TRSTX – ICE
S16
PD_OFF – ICD3
ICD3
ICD3 – PD_ON
S17
PD_OFF – ICD2
ICD2
ICD2 – PD_ON
S18
PD_OFF – ICD1
ICD1
ICD1 – PD_ON
S19
PD_OFF – ICD0
ICD0
ICD0 – PD_ON
S20
PD_OFF – BREAK
BREAK
BREAK – PD_ON
Default:
S14 = INITX–ICE
S16 = OFF–ICD3
S20 = OFF–ICD0
Note:
1) If the in-circuit-emulator (ICE) is used, the default settings have to be used.
MCU-AN-391005-E-V17
Getting Started
Chapter 5 Jumpers and Switches
Setting
Description
INITX is controlled by the evaluation board
INITX is controlled by the emulator
TRSTX is controlled by the evaluation board
TRSTX is controlled by the emulator
Disconnect pull-down resistor to ICD3
Connect pull-down resistor to ICD3
Disconnect pull-down resistor to ICD2
Connect pull-down resistor to ICD2
Disconnect pull-down resistor to ICD1
Connect pull-down resistor to ICD1
Disconnect pull-down resistor to ICD0
Connect pull-down resistor to ICD0
Disconnect pull-down resistor to BREAK
Connect pull-down resistor to BREAK
S15 = TRSTX–ICE
S17 = OFF–ICD2
- 16 -
S20 = BREAK-ON
S18 = OFF–ICD1
© Fujitsu Microelectronics Europe GmbH

Advertisement

Table of Contents
loading

Table of Contents