Power Up The Emulation System - Fujitsu MB91460 Getting Started

Emulation system
Hide thumbs Also See for MB91460:
Table of Contents

Advertisement

After connecting the boards it is necessary to connect the DSU-FR Cable MB2198-10 and
the power supplies.
5. Connect the DSU-FR Cable MB2198-10 to the evaluation board.
6. Connect the 16 V DC power supply to the port 'DC in' and to 230 V. Please, be
aware, that 'SW2 Power' is off.
7. Provide the 9 V DC power supply and connect it to 230 V. The following figure shows
the correct polarisation. Do not power up the evaluation board by connecting the
power supply yet.
Figure 8: The Correct Polarisation of the 9 V DC Power Supply.
The following figure shows the cabling of the boards.
Figure 9: Cabling the Adapter Board, Probe Cable and Evaluation Board

4.4 Power up the Emulation System

To avoid damages, please always follow this procedure to power up the emulation system.
1. Switch on the main switch at the back of the emulator MB2198-01. The 'Power' LED
and the 'UVCC' LED have to be illuminated.
2. Power on the MB91V460 Adapter Board (MB2198-300) 'SW2 Power'. The 'Power'
LED has to be illuminated.
3. Power on the evaluation board SK-91460-MAIN V1.2
Rule 3: To power down the emulation system, please follow the procedure reversely.
MCU-AN-391005-E-V17
Getting Started
Chapter 4 Installation of the Emulation System
GND
- 14 -
9 V
© Fujitsu Microelectronics Europe GmbH