22m -xx
Current counter status (for version 1.04.00 and up)
m:=0
to
m:=1
Table value:
Example:
Expl.:
22m -xx
Current status for apparent demand (for version 1.04.00 and up)
m:=3
to
m:=4
Table value:
Example:
Expl.:
m: Registration period (m:=0,1)
0 Registration period MP1
1 Registration period MP2
xx: desired value (Counter/Total)
00 Counter 1
01 Counter 2
... etc.
15 Counter 16
64 positive Total 1
65 positive Total 2
66 positive Total 3
67 positive Total 4
80 negative Total 1
81 negative Total 2
82 negative Total 3
83 negative Total 4
b7b6b5b4b3b2b1b0: Status
b0 bis b7 usually have the value "0". Exceptions:
b0 = '1' on overflow of the energy register (999999999)
b1 = '1' on overflow of the demand register (99999999)
b2 = '1' when the signal condition monitoring has been triggered,
no data telegrams or errors from analogue input for at least 60 se-
conds
b3 = '1' on parameter change for the energy register
b4 = '1' if the register is currently in test mode
Energy register has flown over.
m: Registration period (m:=3,4)
3 Registration period MP1
4 Registration period MP2
xx: desired apparent demand value
00 Apparent demand 1
01 Apparent demand 2
b7b6b5b4b3b2b1b0: Status
b0 to b7 usually have the value „0". Exception:
b1 = '1' on over flow of the demand register
Demand register has flown over
b7
b6
b5
b4
b3
0
0
0
0
0
b7
b6
b5
b4
b3
0
0
0
0
0
b2
b1
b0
0
0
1
b2
b1
b0
0
1
0
A 13