3.
SAN Functions
Server Linkage Functions
The controller firmware version of the ETERNUS DX must be V10L86 or later.
The Veeam Storage Integration license must be obtained and registered in the ETERNUS DX.
iSCSI and FC host interfaces are supported in Veeam Storage Integration for the connection between backup
proxies and the ETERNUS DX.
To connect a Backup Proxy with the ETERNUS DX via an FC, the host affinity settings must be configured for
the Backup Proxy using ETERNUS CLI. For more details, refer to "ETERNUS CLI User's Guide".
To enable the ETERNUS DX storage snapshot integration with Veeam Backup & Replication, FUJITSU Plug-In
for Veeam Backup & Replication must be installed to the Veeam backup server.
If a volume has several snapshot generations and these snapshots have been created with different resolu-
tions, only the oldest snapshot generation can be deleted.
The following volumes cannot be managed or operated by Veeam Backup & Replication:
Volumes used for the Storage Cluster function
-
Virtual Volumes (VVOLs)
-
-
Volumes with Advanced Copy sessions except SnapOPC+ sessions
Volumes with SnapOPC+ sessions created by ETERNUS SF AdvancedCopy Manager
-
Veeam Backup & Replication jobs or operations may fail during a RAID migration, a Thin Provisioning Vol-
ume balancing, or a Flexible Tier Pool balancing.
SnapOPC+ is used for Veeam Storage Integration.
Thin Provisioning Volumes (TPVs) or Flexible Tier Volumes (FTVs) are used as SnapOPC+ copy destination
volumes.
Configure an appropriate maximum pool capacity for the Thin Provisioning function by taking the total ca-
pacity of volumes used for Veeam Storage Integration and the number of snapshot generations into consid-
eration. For more details about the maximum pool capacity setting, refer to "Thin Provisioning Pool Man-
agement" in "ETERNUS Web GUI User's Guide".
Guidelines for the maximum pool capacity for the Thin Provisioning function:
Maximum pool capacity ³ total capacity of TPVs and FTVs + total capacity of volumes for Veeam Storage
Integration ´ (number of snapshot generations + 1)
It is not recommended to use multiple Veeam Backup & Replication for managing a single ETERNUS DX.
In such configuration, an error might occur at the jobs that are in conflict with each other when being exe-
cuted from multiple Veeam Backup & Replication.