3.
SAN Functions
Data Migration
For online Storage Migration, the capacity of the migration destination volume must be the same as the
•
migration source volume.
For offline Storage Migration, stop server access to both the migration source volume and the migration
•
destination volume during a migration.
For online Storage Migration, stop server access to the migration source volume and the migration destina-
tion volume before starting a migration. In addition, do not access the migration source volume from the
server during a migration.
Online storage migration can be manually resumed on the following volumes after the process (of deleting
•
a copy session) is complete.
TPV/FTV capacity optimization is running
-
-
Flexible Tier Migration is running
An Advanced Copy session exists
-
For the migration destination device, the FC port mode needs to be switched to "Initiator" and the port pa-
•
rameter also needs to be set.
Make sure to delete the migration path after Storage Migration is complete.
•
FUJITSU Storage ETERNUS DX500 S4/DX600 S4, ETERNUS DX500 S3/DX600 S3 Hybrid Storage Systems Design Guide (Basic)
129
Copyright 2019 FUJITSU LIMITED
P3AM-7722-25ENZ0