Extreme Cache; Host Interface; Figure 114 Extreme Cache Module Installation Diagram - Fujitsu ETERNUS DX500 S4/DX600 S4 Design Manual

Table of Contents

Advertisement

5.
Hardware Configurations
Standard Installation Rules

Extreme Cache

This section describes the standard installation rules for Extreme Caches.
Installation Order
The installation priority order for the Extreme Cache modules is shown below.
1
2.8TB Extreme Cache (1.4TB ´ 2)
2
1.4TB Extreme Cache (700GB ´ 2)
The diagram below shows an Extreme Cache module installation.
Install the Extreme Cache modules in PFM#0 and then PFM#1 according to the priority order.

Figure 114 Extreme Cache Module Installation Diagram

CM#1 connection
PFM#1
PFM#0
CM#0 connection
PFM#1
PFM#0

Host Interface

This section describes the standard installation rules for host interfaces.
Installation Order
The installation priority order for host interfaces is shown below.
1
FC 32Gbit/s (4 ports) (*1)
2
FC 16Gbit/s (8 ports)
3
FC 16Gbit/s (4 ports)
4
FC 8Gbit/s (8 ports)
5
FC 8Gbit/s (4 ports)
6
iSCSI 10Gbit/s (4 ports)
7
iSCSI 10Gbit/s (without SFP+ modules) (4 ports)
8
iSCSI 1Gbit/s (4 ports)
9
FCoE 10Gbit/s (4 ports)
10
FCoE 10Gbit/s (without SFP+ modules) (4 ports)
11
Ethernet 10Gbit/s (4 ports)
12
Ethernet 10Gbit/s (without SFP+ modules) (4 ports)
13
Ethernet 1Gbit/s (8 ports)
*1: Installable in the ETERNUS DX500 S4/DX600 S4 only.
FUJITSU Storage ETERNUS DX500 S4/DX600 S4, ETERNUS DX500 S3/DX600 S3 Hybrid Storage Systems Design Guide (Basic)
BBU#2
BBU#1
BBU#0
Front View of a Controller Enclosure
Copyright 2019 FUJITSU LIMITED