Description
3.5 Description of the components
Figure 3-4
See also
Gating of the power semiconductors (Page 241)
Selecting Safe Torque Off (Page 241)
Actual value channels (Page 242)
40
X11 – X14, X21 –
Gating of the power semiconductors, inverter phase u
X24
X15, X16, X25, X26 Gating of the power semiconductors, crowbar
X31 – X34, X41 –
Gating of the the power semiconductors, inverter phase v
X44
X35, X36, X45, X46 Gating of the power semiconductors, braking chopper
X51 – X54, X61 –
Gating of the power semiconductors, inverter phase w
X64
X241, X242
Selecting Safe Torque Off
X70 – X79
Actual value channels 0 to 9
X81
Trip line
X200 – X202
DRIVE-CLiQ interfaces
X231, X232
Analog and digital outputs
S5.0
Switches of the analog inputs, voltage/current measurement AI0
S5.1
Switches of the analog inputs, voltage/current measurement AI1
X221, X222
Analog and digital inputs, temperature sensor connections
LEDs
Diagnostics via LEDs
X210
Electronics power supply
Overview of PSA interfaces