Selecting data sets
Figure 8-7
In this menu, you can parameterize the following data sets:
● Command data set
● Drive data set
● Motor data set
● Speed encoder data set
● Power unit data set
The data set number set for "AOP" specifies which index (data set) of the assigned parameter
in the AOP is displayed. This is independent of which data set is currently activated in the drive.
Example of a data set selection
You can set separately the main setpoints in the terminal mode and PROFIBUS mode using
two command data sets. This requires that you have parameterized this beforehand.
● In terminal mode p1070[1]
● In PROFIBUS mode p1070[0]
The command data set that must be enabled for setting the relevant main setpoint is indicated
1)
in the square parentheses of the parameter [ ]. In the factory setting, command data set 0 is
active.
Permanent parameter acceptance
The parameters are saved on the CompactFlash card using this menu.
You can find further information on this in the "Permanently saving the parameters" section.