2.8

Inverter type and safety labels

Figure 9: Location of type label
The type label is shown in figure 8. Different type labels can be found on the models M4-TL-US
WB,M5-TL-US WB,M6-TL-US WB,M8-TL-US WB, and M10-TL-US WB. The inverter serial num-
ber can be found on the type label. Please note that capital letters in Serial Number are used as
placeholders to indicate the variable information for the M4-TL-US WB,M5-TL-US WB,M6-TL-US
WB,M8-TL-US WB, and M10-TL-US WB
The main caution labels in English and French are on the left side of the inverter.
NOTES:
MATERIAL:White Polyester 0.05+PET(#25)
PARTA&B Background Color Panton Yellow C
Text Color :Black
Adhesive: KK#9
Must meet delta spec 10000-0085
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF
DELTA ELECTRONICS, INC. AND SHALL NOT BE REPRODUCED OR
USED AS THE BASIS FOR THE MANUFACTURE OR SELL OF
APPARATUSES OR DEVICES WITHOUT PERMISSION.
DESCRIPTION:
Warning Label
USED ON
Common
FRAME NAME: DF-MEA4V-2R03.DWG
M6-TL-US
DC Max System Voltage:
DC Operating Voltage Range:
DC Full Power MPPT Range:
DC Max. Input Current per String:
AC Nominal Output Voltage:
AC Operating Voltage Range:
183-228V
AC Max. Continuous Output Current:
AC Max. Continuous Output Power:
AC Nominal Output Frequency:
AC Operating Frequency Range:
0.99(0.85i-0.85c adj.)
Output Power Factor:
Enclosure Type: Type 3R
Grid Support Utility-Interactive Transformerless Inverter
Special Purpose Utility-Interactive.
Ambient Temperature:-30~+65℃ Derating >45℃
CSA C22.2 NO.107.1-01
UL1741 UL1699B
This device complies with part 15 of FCC rules:
operation is subject to the following two conditions:
(1)this device may not cause harmful interference and
(2)this device must accept any interferene received,
including interference that may cause undesired operation.
Rev:00
Data Code:YYWW
S/N:MMMYYWWZZZZ
Caution!
*Risk of Electric shock,Do not remove or destroy this label.
*Do not remove cover.No user serviceable parts inside.refer
ervicing to qualified service personnel.
*Both AC and DC voltage sources are terminated insied this
equipment.Disconnect each circuit individually before servicing.
*When the photovoltaic array is exposed to light,it supplies DC
voltage to the equipment
*Risk of Electric shock from energy stored in capacitor.Do not
remove cover until 5 minutes after disconnection all sources of supply.
*Normally grounded conductors may be ungrounded and energized
when a ground fault is indicated.
*Voltage and frequency trip points are factory set to current
UL1741.2 and IEEE 1547/1547.1 standards.
*Warning:More than one live circuit.see Diagram in manual.
*Hot surfaces.To reduce the risk of burns,do not touch.
MISE EN GARDE
*Risque de choc électrique,ne pas enlever ou détruire cette étiquette.
*Pour le raccordement voir le manuel.
*Le boîtier ne doit en aucun cas être ouvert.Aucun composant interne n´est
à entretenir.Reportez-vous à un technicien qualifé pour tout entretien.
*Les deux sources de tension CA et CC sont résiliées à l`intérieur de cet
équipement.Débranchez chaque circuit individuel avant tout entretien.
*Quand les panneaux photovoltaïque sont exposés à la lumière,ils
fournissent une tension en courant continu à l´équipement.
*Risque de choc électrique à partir d´énergie stockée dans les
condensateurs.Retirer le couvercle du boîtier au moin 5 minutes après
avoir débranché toutes les sources d´approvisionnement.
*Attention:Risque de choc électrique.Les conducteurs DC de ce système
photovoltaïque ne sont pas fondées et peuvent être alimentés.
*Attention:Risque de choc électrique.Les conducteurs DC de ce système
photovaltaic sont normalement mis à la terre,mais deviendra intermittence
terre sans indication lorsque le variateur mesure le photovoltaïque
isolement.
*Surface chaude.Pour réduire le risque de brûlures ne pas toucher.
. The inverter serial num-
DRAWN:
APPROVE:
DIMENSIONAL TOLERANCES
( V )
DECIMALS
X
:±0.3
X.X
:±0.2
X.XX :±0.1
CONFIDENTIAL
A4
SIZE
ECN NO.
UNIT
600V
50~550V
200~480V
12A
208V
240V
211-264V
24A
24A
5472W
6000W
60Hz
59.3~60.5Hz
Pending
240436
Integrated
PV AFCI
Type 1
Made In China
Jerry
DESIGN:
Brighton
DATE:
( )
( )
( )
<50
:±0.1
<50
:±0.15
<50
>50~100 :±0.15
>50~100 :±0.2
>50~100 :±0.
>100~200 :±0.2
>100~200 :±0.25
>100~200 :±0.
>200~
:±0.2%
>200~
:±0.25%
>200~
PART NO.:
15
3****
THIRD ANGLE
PROJECTION
mm
SCALE
1:1
SHEET 1
8
:±0.