9.2

Technical data

Model
INPUT (DC)
Maximum system voltage
Nominal voltage
Maximum operating voltage Voc
Operating MPPT range
Maximum input current (per MPPT)
Maximum short circuit current @ STC
Maximum DC/AC ratio
DC disconnect
MPP tracker
Input strings available
OUTPUT (AC)
Nominal power @ 240V
Maximum output power
Voltage range
Maximum continuous current
Nominal frequency
Frequency range
Adjustable frequency range
Night consumption
THD @ nominal power
Power factor @ nominal power
Adjustable power factor range
Acoustic noise
GENERAL SPECIFICATION
Maximum efficiency
CEC efficiency
Operating temperature range
Storage temperature range
Humidity
Maximum operating altitude
1) Adjustable value, limited by the output capability of battery pack
2) Adjustable value, Limited by the maximum allowed voltage of battery pack
52
SPECIFICATIONS
M4-TL-US
M5-TL-US
12 A
12 A
15 A / 15 A
15 A / 15 A
2
2
2 - 2
2 - 2
3840 W
4800 W
4000 W
5000 W
16 A
20 A
97.0 % @ 208 V
97.5 % @ 208 V
97.5 % @ 240 V
97.5 % @ 240 V
M6-TL-US
M8-TL-US
600 V
380 V
540 V
50 V to 480 V
12 A
15 A / 15 A / 15 A
15 A / 15 A / 15 A
1.3
Integrated
3
2 - 2 - 2
2 - 2 - 2
5760 W
7680 W
6000 W
8000 W
183 Vac to 229 Vac @ 208 Vac
211 Vac to 264 Vac @ 240 Vac
24 A
60 Hz
59.3 Hz to 60.5 Hz
50 Hz to 66 Hz
< 1.5 W
< 3 %
> 0.99
0.85i to 0.85c
< 45 dB(A) @ 3 ft (1m)
98%
97.0 % @ 208 V
97.5 % @ 208 V
97.5 % @ 240 V
97.5 % @ 240 V
-22 °F to 149 °F (-30 °C to 65 °C)
de-rating above 113 °F (45 °C )
-40 °F to 185 °F (-40 °C to 85 °C)
0% to 95%
9,843 ft (3,000 m)
M10-TL-US
12 A
12 A
25 A / 25 A
3
2
2 - 2
9600 W
10000 W
32 A
40 A
97.5 % @ 208 V
97.5 % @ 240 V

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M5-tl-usM4-tl-usM8-tl-usM6-tl-usM10-tl-us

Table of Contents