6.0 COMPONENT REPLACEMENT (Cont.)

6.6 Water Inlet Solenoid

Figure 6-8 - Water Inlet Solenoid & Mounting
1) Shut off the water supply to the unit and then
dispense a still coffee (left tap handle) drink to
relief any water pressure in the lines.
2) Shut off power to the dispenser and unplug the
power cord from the wall receptacle.
3) Remove the enclosure top panel and then the
right-side and rear access panels from the dis-
penser.
4) Disconnect the water-supply hose from the
inlet solenoid.
5) Remove the two back-panel, Phillips screws
securing the inlet solenoid bracket.
6) Partially remove the inlet solenoid and then
remove the dispenser water-inlet hose from it.
© 2019, Cornelius Inc. All Rights Reserved
7) Connect the dispenser water hose to the
replacement solenoid.
8) Reinstall the solenoid in reverse order.

6.7 Power Supply (24Vdc)

1) Shut off power to the dispenser and unplug the
power cord from the wall receptacle.
2) Remove the enclosure top panel and then the
right-side access panel from the dispenser.
3) Disconnect the AC wiring from the top of the
power supply (Fig. 6-9).
Figure 6-9 - 24Vdc Power Supply & Mounting
4) Remove the screws securing the power supply
to the enclosure rail.
5) Remove the power supply partially from the
enclosure and disconnect the DC wiring from
the bottom terminals. Then remove it entirely.
6) Install the new power supply in reverse order.