3.0 SYSTEM OPERATION (Cont.)
3.3 Component Functions (Cont.)

3.3.9 Ice Bank Chilling System

In the base of the unit resides the insulated ice
bank assembly. It is comprised of a refrigeration
unit (in the rear of the enclosure), a water/ice res-
ervoir, an agitator/circulation pump to control ice
formation and circulate cooling water, an ice sen-
sor and a control module, The control module
manages the refrigeration system and the agitator
based on feedback from the ice sensor. Water
from the inlet solenoid is routed through a stain-
less steel coil in the ice bank for chilling. As well,
cooling lines from the circulation pump are routed
into the product cabinet where a fan circulates
chilled air.
Figure 3-16 - Ice Bank Sensor & Agitator Motor
Figure 3-15 - Ice Bank and Controller Module