Expansion Master Unit And Expansion Slave Unit; Models And Specifications - Omron CK3M Series User Manual

Programmable multi-axis controller hardware
Hide thumbs Also See for CK3M Series:
Table of Contents

Advertisement

3-6
Expansion Master Unit and Expan-
sion Slave Unit
This section describes the Expansion Master Unit and the Expansion Slave Unit.
3-6-1

Models and Specifications

Models and Outline of Specifications
The models and outline of specifications are given below.
Unit type
Expansion Master Unit CK3W-EXM01
Expansion Slave Unit
Specifications
Expansion cable
Power consumption
Dimensions (height ×
depth × width)
Weight
CK3M-series Programmable Multi-Axis Controller User's Manual Hardware (O036)
Model
CK3W-EXS02
For connection between the Expansion Master Unit and the Expansion Slave
Unit, be sure to use the following cable.
CK3W-CAX003A (0.3 m)
CK3W-EXM01: 5 V 0.4 W max.
CK3W-EXS02: 5 V 0.2 W max.
90(H)/80(D)/31.6(W)
CK3W-EXM01: 100 g max.
CK3W-EXS02: 130 g max. (including End Cover)
3 Configuration Units
3-59
3

Hide quick links: