Address Switch Setting; Encoder Connector Specifications - Omron CK3M Series User Manual

Programmable multi-axis controller hardware
Hide thumbs Also See for CK3M Series:
Table of Contents

Advertisement

3 Configuration Units
3-3-4

Address Switch Setting

This Unit is equipped with a PMAC3 style DSPGate3 IC.
Refer to the Power PMAC User's Manual (Cat. No. O014) for the PMAC3 style DSPGate3 IC.
The address switch settings are used to set the Gate3 Index.
The setting range is from 0 to F. (Factory setting: 0)

Address switch setting

0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
For example, if the address switch setting is 0, the Gate3 Index becomes 0.
In this case, this Unit is accessed with a Gate3[0] data structure.
Make sure that the address switch settings of Units do not overlap.
If they overlap, the Sys.Status register CK3WConfigErr becomes 7.
Refer to 6-4 Sys.Status Register on page 6-9 for Sys.Status.
One CK3W Unit in the system supplies servo clock and phase clock signals to all the other Units.
The supply-source CK3W Unit must be installed to the CPU Rack.
Connect the Unit with the smallest address value to the CPU Rack because, by default, it is the supply
source of clock signals.
You may specify the Unit with a desired address as the clock supply source by setting the register.
If the Unit that serves as the clock supply source is connected to the Expansion Rack, an error occurs
because the CPU Unit cannot recognize clock signals.
If this error occurs, the Sys.Status register Sys.NoClocks becomes 1.
3-3-5

Encoder Connector Specifications

The electrical specifications for the encoder connector are as follows.
3-16
Power PMAC
"Gate3" Index
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
CK3M-series Programmable Multi-Axis Controller User's Manual Hardware (O036)