6-2

Using the Indicators to Check Errors

6-2-1

Indicator Types

The Motion Controller indicators used for error checks and their functions are as shown below.
Unit
Power Supply Unit PWR
CPU Unit
CK3W Unit
6-2-2

Procedure for Identifying Errors

When an error occurs in the Motion Controller, check the indicators with the following flowchart to first
identify if either a "non-fatal error in the CPU Unit" or a "fatal error in the CPU Unit" has occurred.
CK3M-series Programmable Multi-Axis Controller User's Manual Hardware (O036)
Indicator name
Shows that power is being supplied to the Unit.
PWR
Shows the CPU Unit internal power status.
RDY
Shows whether the CPU Unit is in operation-ready status.
ERR
Shows the CPU Unit watchdog timer error status.
ECAT LINK
Shows the link status of EtherCAT communications.
ECAT ACT
Shows the data communications status of EtherCAT communications.
Ethernet LINK
Shows the link status of Ethernet communications.
Ethernet ACT
Shows the data communications status of Ethernet communications.
PWR
Shows the Unit internal power status.
6 Troubleshooting
Description
6
6-3