Roland TrueVIS VG2-640 Setup Manual page 52

Hide thumbs Also See for TrueVIS VG2-640:
Table of Contents

Advertisement

1. Assembly and Ink Filling
Close the ink slot cover.
E
When the screen shown below appears, remove the drain bottle and discard the dis-
F
charged fluid.
EMPTY
DRAIN BOTTLE
IM PORTANT
When you remove the drain bottle, a few drops of discharged fluid may come out of the drain fun-
nel. Exercise caution to prevent this fluid from soiling your hands or the floor.
CAUTION
WARNING
CAUTION
Quickly attach the emptied drain bottle to the machine once more.
G
Press [ENTER].
H
When the screen shown in the figure appears, filling with ink is finished.
SETUP SHEET
50
2.Installation
Before you detach the drain bottle, be sure to wait for the screen to display
"EMPTY DRAIN BOTTLE." After discarding the discharged fluid, promptly
attach the drain bottle to the machine.
Failing to follow this procedure may cause discharged fluid to flow out of the
tube and spill, soiling your hands or the floor.
Never place discharged fluid or ink near an open flame.
Doing so may cause fire.
To store discharged fluid temporarily, place it in the included drain bottle
or in a durable sealed container such as a metal can or polyethylene tank,
and cap the container tightly.
Any spillage or vapor leakage may cause fire, odor, or physical distress.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Truevis vg2-540

Table of Contents